Research context and placement
A liquid interface addresses blood/mucus fouling and fogging on an endoscope cap, fitting antifouling during host contact.
Research overview and key contributions
This study addresses fogging and blood/mucus fouling on disposable endoscope caps. SHIELD-C is a disposable endoscope cap combining a PDMS brush with silicone oil.
Its transparent liquid interface and lubricant replenishment address blood and mucus fouling.

AI-generated concept of SHIELD-C’s PDMS-brush/silicone-oil interface and lubricant replenishment described in the public abstract. The cap outline and bands are functional symbols, not actual geometry, experimental imagery or clinical outcomes.
Judgment uses the publisher-registered Crossref abstract only. Arrows denote optical path and replenishment, not transmittance, restored vision or automated supply. Mounting hardware, brush molecular arrangement, thickness and replenishment procedures are not reproduced. Article-depth work remains blocked.
This is not a reproduced paper figure and does not establish permission to reuse the original figure.
Generated in ChatGPT on the web from concepts verified in the public abstract and independently reviewed within that abstract-only scope. This does not claim verification of the main text or supplements. Display processing is limited to WebP encoding, without cropping or content editing.
Open challenges
Editorial question: Does performance persist during surgery despite lubricant loss and residues? Abstract validation is in vitro and ex vivo.
Comparison context
Match lens/cap geometry, foulants, temperature/humidity, cleaning/replenishment cycles and visibility criteria.
Related external research
A bioinspired omniphobic surface coating on medical devices prevents thrombosis and biofouling
Both retain liquid interfaces to resist fouling; #93 focuses on visibility and a replenishable cap.
Vascular thrombosis endpoints do not establish endoscopic fog or mucus removal.
Abstract checkedCorresponding-author verification
Jungmok Seo: corresponding authorThis record concerns Jungmok Seo’s correspondence designation. Author order or an asterisk alone is not treated as confirmation; this check is separate from verification of the research content.
- Correspondence evidence source ↗
10.1021/acsami.6c04312
resource_doi and references; file am6c04312_si_002.pdf · public_publisher_supplement_repository_metadata_read
- Correspondence evidence source ↗
* Corresponding author. E-Mail: [redacted] (Prof. Jungmok Seo), [redacted] (Seung Hoon Lee, MD, PhD)
Supporting Information page S1: title, author list, corresponding-author note and named emails · public_publisher_supplement_first_page_read
- Main-text review scope
- The publisher-registered Crossref abstract was read. ACS direct retrieval failed; publisher-site full-text verification is not claimed.
- Supplementary review scope
- Only the S1 cover, author list and correspondence notice in the public ACS Figshare supplementary information were read. The supplementary experiments, figures and results were not fully verified.
- Pending verification
- Verify ex vivo models, safety and durability for DOI 10.1021/acsami.6c04312 in school Chrome; do not label this a clinical trial.
COVERAGE & OUTREACH
Coverage and outreach
Links are checked for their relationship to this paper. Media publication does not establish independent reporting or additional experimental validation.
내시경 캡 연구, ACS Applied Materials & Interfaces 표지 논문 선정 ↗
The disposable-endoscope-cap news card and ACS AMI 18(25) match #93's exact title, authors and DOI linked on the same site.
Partial body read The actual news card and home-page paper identity were read. Cover selection is recorded as the author's announcement; the publisher's cover caption remains unverified.
Sources and verification scope
The publisher-registered Crossref abstract was read. ACS direct retrieval failed; publisher-site full-text verification is not claimed.
- Public publication baseline ↗ · #93 · 2026-10-03
- Crossref metadata ↗: Only public bibliographic metadata registered with Crossref was checked. This does not mean that the publisher page, abstract, or full text was read; full-text verification in the school Chrome session remains pending. Manual comparison found presence/absence of the article A. This was adjudicated as a minor bibliographic variation referring to the same paper; original values were retained. license_urls lists registered links and does not establish permission to redistribute text or figures. It may include TDM or posting-policy links.
- Source for updated publication metadata ↗
Bibliographic and publication-status check; separate from main-text review. - A Disposable Endoscope Cap Maintaining Clear Surgical Visualization under Fogging and Fouling ↗
publisher_registered_abstract_via_Crossref · Crossref response message.abstract, title and DOI; read 2026-10-03; distinguished from direct publisher-site access. - A Disposable Endoscope Cap Maintaining Clear Surgical Visualization under Fogging and Fouling ↗
publisher_direct_access_failed · ACS resolved URL returned retrieval error; 2026-10-03 - A bioinspired omniphobic surface coating on medical devices prevents thrombosis and biofouling ↗
public_external_abstract · Abstract and DOI metadata; read 2026-10-03.