1022026Summary based on the full text
Advanced Science, e78062 (2026), Early View
Stretchable conductors and interconnectsLiquid conductors
PVA-modified liquid-metal particle ink that conducts as sprayed, giving 1.5 × 10^6 S m−1 without post-treatment and continuity beyond 200% strain.
1012026Summary based on the full text
Materials Science and Engineering R: Reports, 171, 101285 (2026)
Device integration and packagingJoining and protective packaging
Review of packaging rigid IC chips into soft electronics across three architectures and three interface requirements; sub-100 μm fine pitch is the key barrier.
1002026Summary based on the full text
Small Science, 6(9), e70402 (2026)
Device integration and packagingFoundations · connection under review
Review of wearable thermoelectric devices that links skin contact, stretchable design and heat-flow paths to performance; Table 4 spans up to 25.34 μW cm−2 K−2.
0992026Summary based on the full text
Burns & Trauma, 14, tkag055 (2026)
Biological responses and surface designImmune and foreign-body responses
A review of bioadhesive hydrogels as immunomodulatory interfaces for chronic wounds, grouped into protective, bioactive, stimuli-responsive and sensing designs.
0982026Summary based on the full text
Advanced Materials, e74385 (2026)
Materials in contact with tissueTissue repair and biofabrication
A moldable PVA/gelatin/nanocellulose hydro-dough stopped calvarial sinus bleeding within 50 s and, with bone fragments, reached 34.80% BV/TV at 8 weeks.
0972026Summary based on the full text
Advanced Functional Materials, 36(67), e77191 (2026)
Biological responses and surface designImmune and foreign-body responses
An oxygen-releasing, hMSC-laden bioink printed into diabetic mouse wounds by a vision-guided robot accelerated wound closure relative to Tegaderm.
0962026Summary based on the full text
Materials Today Bio, 39, 103405 (2026)
Biological responses and surface designAntifouling and lubricious surfaces
FLUID maintains a lubricated interface using silicone oil stored in a porous ureteral-stent wall. Initial bacterial adhesion fell by over 94% at 72 hours, while bacterial recovery in a 14-day mature-biofilm model fell by about 21% or 28%, depending on the comparator stent.
0952026Summary based on the full text
Materials Today Bio, 38, 103299 (2026)
Biological responses and surface designBiological interaction control
Review of piezoelectric antibacterial platforms driven by multiple energy inputs and AI, covering mechanisms, material design, applications and reporting gaps.
0942026Summary based on the full text
ACS Applied Materials & Interfaces, 18(25), 34821-34834 (2026)
Biological responses and surface designAntifouling and lubricious surfaces
A single-use endoscope cap with a PDMS brush and silicone oil interface; one sponge refresh restored visual clarity from 84.3 ± 4.8% to 98.9 ± 1.2%.
0932026Summary based on the full text
Nature Communications, 17, 5526 (2026)
Materials in contact with tissueWet tissue adhesion
STAT, a quinone-mediated double-network hydrogel, bonded to wet porcine skin at 273 kPa lap-shear strength and stopped mouse liver bleeding within 10 s.
0922026Summary based on the full text
Bioactive Materials, 61, 210 - 228 (2026)
Biological responses and surface designAntifouling and lubricious surfaces
ELFS, a polydopamine-anchored lubricant-infused stent coating, kept rabbit bile duct stents open for 2 months while uncoated stents became fully occluded.
0912026Summary based on the full text
Advanced Materials, 38(19), e15767 (2026)
Materials in contact with tissueAnalyte transport
Sulfate and calcium treatment order tuned PVA–alginate hydrogel pores from 65 nm to 2.5 µm, setting glucose sensor ranges for sweat and interstitial fluid.
0902026Summary based on the full text
Small, 22(17), e10949 (2026)
Device integration and packagingJoining and protective packaging
MOLE combines bonded silicone–Parylene C layers with a lubricated surface. Insulation was tested by accelerated aging at 85 °C, and device degradation and tissue responses by 7-day subcutaneous implantation in mice; these results do not establish a long-term human implant lifetime.
0892026Summary based on the full text
Advanced Healthcare Materials, 15(12), e04939 (2026)
Biological responses and surface designImmune and foreign-body responses
A spray-printed PVA/liquid-metal patch delivered screened stimulation to diabetic mouse wounds, leaving 23.4% wound area at day 3 versus 66.8% untreated.
0882026Summary based on the full text
ACS Environmental Au, 6(1), 125-133 (2026)
Biological responses and surface designAntifouling and lubricious surfaces
A graphene oxide and perfluoropolyether coating on PVDF kept salt rejection above 99.7% at 15.4 LMH flux for 24 h of distillation with 0.4 mM surfactant.
0872025Summary based on the full text
ACS Applied Materials & Interfaces, 17(51), 70047 - 70058 (2025)
Device integration and packagingFoundations · connection under review
Nitinol–PMMA composite in which induction heating drives shape recovery and CO2 foaming; foaming raised impact strength by 142% and tuned model drug release.
0862025Summary based on the full text
Advanced Electronic Materials, 11(19), e00475 (2025)
Device integration and packagingJoining and protective packaging
Review of OLED encapsulation from glass lids to thin-film hybrid multilayers, linking WVTR targets near 10−6 g m−2 day−1 to flexible and bioelectronic devices.
0852025Summary based on the full text
Science Advances, 11(37), eadz1228 (2025)
Biological responses and surface designBiological interaction control
TAB combines a lubricated interface with immobilized BDNF to reduce nonspecific attachment and support neuronal interactions. Representative single-unit recordings in mice extend to 12 months; electrode-level statistical comparisons cover a separate 8-month period.
0842025Summary based on the full text
Small, 21(34), 2501590 (2025)
Device integration and packagingFoundations · connection under review
PFPE sealing of a nanoribbon-rigidified ZIF-8 membrane gave ideal H2/N2 selectivity of 209; added plasma fluorination raised ideal H2/CH4 selectivity to 1218.
0832025Summary based on the full text
Advanced Materials Interfaces, 12(14), e00353 (2025)
Biological responses and surface designAntifouling and lubricious surfaces
A 10 s two-step perfluoropolyether dip coating gave 12 materials a ~110° contact angle, cut friction from 0.22 to 0.08 and reduced B. cereus attachment by 91.2%.
0822025Summary based on the full text
Advanced Healthcare Materials, 14(1), 2401735 (2025)
Device integration and packagingComponent assembly and fabrication
A vision-guided 6-axis robot printer made wound-matched wireless stimulation patches; in vitro, stimulation sped fibroblast and endothelial cell migration.
0812024Summary based on the full text
Small, 20(43), 2402431 (2024)
Biological responses and surface designBiological interaction control
A lubricant-coated PDMS organ chip recovered 94.9% of dopamine and 98.6% of levodopa in cell-free tests, versus 83.2% and 89.6% in a conventional PDMS chip.
0802024Summary based on the full text
npj Flexible Electronics, 8, 39 (2024)
Device integration and packagingComponent assembly and fabrication
d-HAPT joins dissimilar electronic materials through moisture-induced chain entanglement in dried PVA–tannic acid layers. Dry–dry bonding uses interfacial water and heat; wet–dry bonding uses hydrogel moisture. Wet–wet and dry-material–tissue adhesion remain limited.
0792024Summary based on the full text
Advanced Materials Technologies, 9(10), 2400157 (2024)
Materials in contact with tissueFoundations · connection under review
A salting-out hydrogel ink kept gelation below room temperature for direct ink writing, yielding printed hydrogels with Young's moduli of 0.193–1.072 MPa.
0782024Summary based on the full text
ACS Nano, 18(19), 12210-12224 (2024)
Device integration and packagingSensor and actuator integration
A wireless, chip-less strain-sensing suture followed a reconstructed porcine Achilles tendon for 10 weeks; strain fell to 5.83% (normal tendon: 4.38%).
0772024Summary based on the full text
Biosensors & Bioelectronics, 255, 116257 (2024)
Materials in contact with tissueTissue-adaptive mechanics
Nanoclay and carbon nanotube fillers set a 3D-printable hydrogel ink to 10–300 kPa modulus and about 20 S/m conductivity for a ring-shaped finger sensor.
0762024Summary based on the full text
Advanced Electronic Materials, 10(8), 2400013 (2024)
Device integration and packagingSensor and actuator integration
A self-healing, adhesive hydrogel-Ecoflex triboelectric nanogenerator gave about 180 V and 0.8 μA, and a power management circuit charged capacitors to 5 V.
0752024Summary based on the full text
Advanced Materials Technologies, 9(11), 2400060 (2024)
Materials in contact with tissueTissue repair and biofabrication
A robot-mounted depth camera guides in situ printing of multiple inks into wounds; spray mode covered a 10 cm × 10 cm area 12 times faster than extrusion.
0742024Summary based on the full text
Industrial Chemistry & Materials, 2(3), 361-377 (2024)
Stretchable conductors and interconnectsLiquid conductors
A review of liquid-based conductors, liquid-infused encapsulation and liquid-based adhesives for bioelectronics, with the reported limits of each material type.
0732024Summary based on the full text
Chemical Engineering Journal, 482, 149043 (2024)
Biological responses and surface designFoundations · connection under review
Titanium coating pairing immobilized BMP-2 with a lubricant layer; in rabbit femurs it resisted MRSA and gave ~45 N nail pull-out force versus ~5 N for LOIS.
0722024Summary based on the full text
Advanced Functional Materials, 34(14), 2312740 (2024)
Biological responses and surface designAntifouling and lubricious surfaces
A lubricant-infused V4D4/fluoropolymer coating stayed crack-free after 2000 cycles at 150% strain and reduced foreign body reaction around hydrogels in mice.
0712024Summary based on the full text
Advanced Functional Materials, 34(31), 2311696 (2024)
Stretchable conductors and interconnectsLiquid conductors
Stretchable liquid-metal electrodes coated with rGO-wrapped EGaIn particles resolved ascorbic acid, dopamine and uric acid peaks after 200 cycles of 30% strain.
0702023Summary based on the full text
Advanced Science, 10(30), 2303651 (2023)
Materials in contact with tissueWet tissue adhesion
A tannic acid double-network hydrogel patch that self-heals, resists swelling and bonds to porcine skin (≈35.98 kPa); it stopped mouse liver bleeding in 10 s.
0692023Summary based on the full text
International Journal of Bioprinting, 9(5), 765 (2023)
Stretchable conductors and interconnectsConductive fibers and stretchable electrodes
A 3D-printable PVA/tannic acid/PAA hydrogel ink printed at about 100 μm resolution; with 6 mg/mL CNT it reached ~0.95 S/m and regained conduction after cutting.
0682023Summary based on the full text
ACS Nano, 17(8), 7296–7310 (2023)
Device integration and packagingSensor and actuator integration
Self-healing polymer vascular graft with a lubricant-swollen lumen and built-in CNT pressure sensor; it resealed 25G needle holes and sensed flow to 100 mL/min.
0672023Summary based on the full text
Bioactive Materials, 25, 555-568 (2023)
Biological responses and surface designAntifouling and lubricious surfaces
Polydopamine-anchored, lubricant-swollen fluoropolymer coating for complex devices; with it, 34 G bioprinting nozzles avoided the drop to 72 ± 5.15% viability.
0662023Summary based on the full text
Advanced Science, 10(12), 2207237 (2023)
Materials in contact with tissueTissue-adaptive mechanics
A PVA/PAA hydrogel with tannic acid and carbon nanotube nanoconfinement resisted swelling, self-healed within 5 min, conducted ≈40 S m−1 and was 3D printable.
0652023Summary based on the full text
Biosensors, 13(1), 83 (2023)
Device integration and packagingComponent assembly and fabrication
A review classifying microfluidic impedance biosensors into six substrate types and contrasting flow cytometry of moving cells with impedance spectroscopy.
0642022Summary based on the full text
2022 IEEE International Ultrasonics Symposium (IUS), 1 - 4 (2022)
Device integration and packagingFoundations · connection under review
A capacitive micromachined ultrasonic transducer with nano-silicon springs beneath its plate gave a calculated surface pressure of 1.1 MPa at 5 VPP (220 kPa/V).
0632022Summary based on the full text
ACS Applied Electronic Materials, 4(4), 1449-1468 (2022)
Biological responses and surface designImmune and foreign-body responses
A review of materials that keep wearable and implantable bioelectronics working long term, organized by physical, biological and interfacial compatibility.
0622022Summary based on the full text
Small, 18(14), 2107060 (2022)
Device integration and packagingFoundations · connection under review
A liquid-permeable Fabry–Perot resonator turned voltage-driven water entry across about 10-nm gaps into a color change, shifting resonance by 87 nm in 0.6 s.
0612021Summary based on the full text
Biotechnology Journal, 16(12), 2100231 (2021)
Materials in contact with tissueWet tissue adhesion
A review of bioadhesives that add antimicrobial, cell-infiltrative, conductive, self-healing or stimuli-responsive functions for tissue healing and sensing.
0602021Summary based on the full text
Nanoscale, 13(43), 18112-18124 (2021)
Device integration and packagingSensor and actuator integration
A core-shell electronic suture senses its own strain (gauge factor ~686) and releases drug from a heat-responsive shell, tested in cells and excised pig skin.
0592021Summary based on the full text
Advanced Science, 8(15), 2100231 (2021)
Biological responses and surface designImmune and foreign-body responses
A lubricated, anti-biofouling coating on silicon neural probes cut insertion impulse by 86% and extended neural recording in mice from 8 to 16 weeks.
0582021Summary based on the full text
Advanced Materials, 33(47), 2005930 (2021)
Biological responses and surface designBiological interaction control
A review of electronic drugs grouped by site and duration of action: ingestible and patch devices, bioresorbable implants and long-term implants.
0572020Summary based on the full text
Science Advances, 6 (44), eabb0025 (2020)
Biological responses and surface designImmune and foreign-body responses
A lubricant-infused stainless-steel implant coating prevented infection in all six rabbits given MRSA-preincubated fixation implants, versus six of six bare.
0562020Summary based on the full text
Scientific Reports, 10, 17454 (2020)
Biological responses and surface designAntifouling and lubricious surfaces
Femtosecond-laser nanostructures engraved into an endoscope lens and filled with lubricant kept over 80% of the view clear after repeated dipping in blood.
0552020Summary based on the full text
Biochip Journal, 14(1), 48-62 (2020)
Biological responses and surface designImmune and foreign-body responses
A review of strategies against the foreign body response to implants: soft and flexible materials, biocompatible coatings, drug delivery and slippery surfaces.
0542019Summary based on the full text
ACS Applied Materials & Interfaces, 11(23), 20615-20627 (2019)
Biological responses and surface designBiological interaction control
Crosslinking hyaluronic acid in carbon nanotube microfibers limited creep and enzyme degradation; a braided six-fiber bundle gave a stable 0.05% strain in DPBS.
0532019Summary based on the full text
ChemNanoMat, 5(6), 729-737 (2019)
Stretchable conductors and interconnectsDeformable substrates
PEDOT polymerized inside rubbery electrospun fiber mats gave about 5 S/cm, resistance that tracked stretching and finger bending, and cardiac cell support.
0522019Summary based on the full text
Advanced Healthcare Materials, 8 (3), 1801146 (2019)
Materials in contact with tissueFoundations · connection under review
A pneumatic chip applied 1 Hz cyclic compression (0–20%) to cardiac fibroblasts in GelMA; 15–20% strain promoted myofibroblast activation, 5–10% did not.
0512019Summary based on the full text
ACS Applied Materials & Interfaces, 11 (5), 5484-5491 (2019)
Biological responses and surface designFoundations · connection under review
Mushroom-shaped PDMS micropillars whose cap edges curl down after 50 nm Al deposition repel liquids down to 14.8 mN/m without any fluorinated coating.
0502018Summary based on the full text
Current Pharmaceutical Design, 24 (45), 5458-5470 (2018)
Materials in contact with tissueFoundations · connection under review
Review of biomaterial microarray platforms that screen cell responses to chemical and physical cues in 2D and 3D, and biosensors for organ-on-chip monitoring.
0492018Summary based on the full text
ACS Applied Nano Materials, 1(12), 6630-6640, (2018)
Device integration and packagingFoundations · connection under review
i-motif DNA cross-links dsDNA-wrapped carbon nanotubes into wet-spun microfibers with ∼27 S/cm conductivity, pH-switchable porosity and H2O2-responsive redox.
0482018Summary based on the full text
ACS Applied Materials & Interfaces, 10 (42), 36094-36101 (2018)
Stretchable conductors and interconnectsConductive fibers and stretchable electrodes
A Kevlar fiber coated with a silver nanoparticle-SBS composite and a fluorinated monolayer kept 0.11-0.28 Ω/cm after 20 washes and repelled water and stains.
0472018Summary based on the full text
Sensors & Actuators B: Chemical, 267, 237-244 (2018)
Device integration and packagingFoundations · connection under review
An extended-gate FET carrying full-length histone H3 detected cathepsin L activity by substrate cleavage, reaching 1 ng/mL compared with 10 μg/mL for fluorometry.
0462018Summary based on the full text
ACS Nano, 12(5), 4259-4268 (2018)
Stretchable conductors and interconnectsConductive fibers and stretchable electrodes
Ag nanoparticles grown inside a multifilament elastic fiber gave a strain sensor with a gauge factor of about 9.3 × 10^5 and a 450% sensing range on first stretch.
0452018Summary based on the full text
ACS Applied Materials & Interfaces, 10 (16), 13293-13303 (2018)
Materials in contact with tissueFoundations · connection under review
Stackable gas-driven bioreactors applied 0–42% cyclic compression to stem cells in 3D GelMA; 42% strain in 5% GelMA raised Runx2, ALP and calcium deposition.
0442018Summary based on the full text
Advanced Materials, 30 (10), 1704189 (2018)
Device integration and packagingSensor and actuator integration
A stingray-like soft actuator with cardiomyocytes on patterned CNT–GelMA and PEG hydrogels and embedded Au microelectrodes was locally paced at 0.5 and 1.0 Hz.
0432018Summary based on the full text
ACS Nano, 12 (2), 932-941 (2018)
Materials in contact with tissueAnalyte transport
A vacuum tip beneath stretchable superamphiphobic PDMS moved droplets and left 0.05–1.4 μL aliquots on wettable spots for glucose, uric acid and lactate assays.
0422018Summary based on the full text
Coatings, 8 (2), 47 (2018)
Biological responses and surface designFoundations · connection under review
Review of pattern transfer, nanoparticle assembly and thiol-ene routes to flexible, transparent superamphiphobic surfaces, with wetting and optical data.
0412018Summary based on the full text
Biomaterials, 153, 85-101 (2018)
Materials in contact with tissueFoundations · connection under review
Review of high-throughput platforms that screen cell responses to biomaterials and delivered molecules in 2D and 3D and analyze genes, glycans and proteins.
0402018Summary based on the full text
Journal of Semiconductors, 39 (1), 011009 (2018)
Stretchable conductors and interconnectsConductive fibers and stretchable electrodes
Review of hybrid microfibers with carbon and metal nanomaterials and hydrogels for textile electronics, pressure sensors, biosensors and tissue engineering.
0392017Summary based on the full text
Nanoscale, 9(47), 18737-18752 (2017)
Materials in contact with tissueFoundations · connection under review
Titanium-coated nanogratings with pulsed stimulation raised MAP2-positive cells from human neural stem cells to 56.2% in 5 days, versus 24.6% on bare flat PUA.
0382017Summary based on the full text
Materials Science and Engineering R: Reports, 119, 1-35 (2017)
Materials in contact with tissueTissue repair and biofabrication
Review of tissue engineering hydrogels controlled in space and time, from micropatterning and 3D bioprinting to timed release, stiffening and degradation.
0372017Summary based on the full text
Nano Today, 15, 91-106 (2017)
Biological responses and surface designFoundations · connection under review
Review tracing inorganic, polymeric and lipid-based drug delivery nanomaterials to FDA approval, noting over 200 nanomaterial products then in clinical studies.
0362017Summary based on the full text
Advanced Functional Materials, 27 (29), 1701618 (2017)
Device integration and packagingFoundations · connection under review
Slanted polymer nanofibers coated with palladium on one side straightened in 4 vol% hydrogen, raising light transmittance by about 65% with a 5.1 s response.
0352017Summary based on the full text
Biomicrofluidics, 11 (4), 044109 (2017)
Materials in contact with tissueFoundations · connection under review
A bioprinted GelMA liver model with an endothelial-lined channel delayed dye diffusion and lessened acetaminophen-induced loss of HepG2/C3A metabolic activity.
0342017Summary based on the full text
Small, 13 (7), 1602865 (2017)
Materials in contact with tissueFoundations · connection under review
A superhydrophobic silver-dendrite track with a droplet stopper moved 1 µL droplets to a Raman spot for successive SERS reads; enhancement factor 6.3 × 10⁵.
0332016Summary based on the full text
Advanced Materials, 28 (34), 7365-7374 (2016)
Biological responses and surface designBiological interaction control
A triboelectric stimulator raised nonviral conversion of mouse fibroblasts into neuronal cells from 6.41% to 14.17% and in skin from 0.04% to 5.86%.
0322016Summary based on the full text
ACS Applied Materials & Interfaces, 8 (28), 17763-17774 (2016)
Materials in contact with tissueFoundations · connection under review
Graphene oxide substrates with 5 μm grooves, ridges and nanoroughness increased neuronal differentiation of human neural stem cells without neurogenic factors.
0312016Summary based on the full text
NPG Asia Materials, 8(4), e262 (2016)
Stretchable conductors and interconnectsFoundations · connection under review
Palladium nanoparticles grown by a galvanic displacement reaction decorated defects in CVD graphene, lowering sheet resistance from about 1 kΩ/sq to 173 Ω/sq.
0302016Summary based on the full text
Materials, 9(2), 116 (2016)
Biological responses and surface designFoundations · connection under review
A review of bio-inspired extreme wetting surfaces, from lotus-type to slippery designs, and their use in cell patterning, spheroid culture, devices and assays.
0292015Summary based on the full text
Journal of Nanomaterials, 2015(1), 975043 (2015)
Device integration and packagingFoundations · connection under review
Few-layer graphene grown on silver nanoparticles from PMMA blocked oxidation in air; a dye Raman peak went from 36,304 to 24,436, versus 113 on bare silver.
0282015Summary based on the full text
Journal of Materials Chemistry C, 3(39), 10293-10301 (2015)
Device integration and packagingFoundations · connection under review
An atomic-layer-deposited SiO2 interlayer under Ta1−xZrxO on InP cut capacitance dispersion from 21.1% to 11.3% and lowered leakage in MOS capacitors.
0272015Summary based on the full text
Nanomaterials, 5(3), 1493-1531 (2015)
Device integration and packagingFoundations · connection under review
Review of conductive textiles, fiber transistors, LEDs and pressure sensors, and textile energy harvesters and storage, with reported outputs and open problems.
0262015Summary based on the full text
Applied Surface Science, 344, 52-56 (2015)
Stretchable conductors and interconnectsFoundations · connection under review
Graphene transistors under 5, 10 and 15 MeV protons showed vacancy defects at 5 and 10 MeV but mainly sp3-type Raman signals and a flat Dirac region at 15 MeV.
0252015Summary based on the full text
Chemistry of Materials, 27 (14), 4964-4971 (2015)
Biological responses and surface designFoundations · connection under review
Hydrogen-induced expansion of Pd on Ag dendrites switched superamphiphobic adhesion reversibly; a 7 μL hexadecane drop held upside down with 31.8 μN in 8% H2.
0242015Summary based on the full text
Scientific Reports, 5, 12326 (2015)
Device integration and packagingFoundations · connection under review
Vacuum-formed dimples in a 275 μm thick superhydrophobic PDMS micro-pillar film steered water droplets; on-chip mixing raised GFP silencing from 70.0% to 78.8%.
0232015Summary based on the full text
Scientific Reports, 5, 12306 (2015)
Stretchable conductors and interconnectsFoundations · connection under review
Oxide-free silicon reduced graphene oxide without added reductants: nanosheets raised C/O from 2.12 to about 9.32, and films on etched wafers had 3.54 KΩ/sq.
0222015Summary based on the full text
IEEE Transactions on Terahertz Science and Technology, 5 (4), 605-612 (2015)
Device integration and packagingFoundations · connection under review
Terahertz probing of silicon nanowires showed Auger scattering offsetting surface-trap decay; SiO2-encapsulated wires had a carrier lifetime of around 1.1 ns.
0212015Summary based on the full text
Advanced Functional Materials, 25 (21), 3114-3121 (2015)
Stretchable conductors and interconnectsConductive fibers and stretchable electrodes
Silver nanowires inside wet-spun SBS fibres bridged silver nanoparticle networks, keeping conduction up to 220% strain; a five-fibre glove read sign letters.
0202015Summary based on the full text
Advanced Materials, 27 (15), 2433-2439 (2015)
Stretchable conductors and interconnectsConductive fibers and stretchable electrodes
Kevlar fibres with Ag nanoparticles in SBS, coated with PDMS and crossed, formed a textile capacitive pressure sensor with 0.21 kPa−1 sensitivity below 2 kPa.
0192015Summary based on the full text
ACS Applied Materials & Interfaces, 7 (6), 3554-3561 (2015)
Device integration and packagingFoundations · connection under review
A PMMA membrane over Pd nanoparticles on single-layer graphene blocked methane, CO and NO2, while the sensor gave a 66.37% average response to 2% hydrogen.
0182015Summary based on the full text
Journal of Power Sources, 274, 1140-1146 (2015)
Device integration and packagingFoundations · connection under review
A self-assembled DTS organosilane coating made carbon black fuel-cell supports hydrophobic and cut CO2 released in a 1.3 V corrosion test from 291 to 177 μL.
0172015Summary based on the full text
RSC Advances, 5(8), 5754-5761 (2015)
Device integration and packagingFoundations · connection under review
Capacitors 2 mm above a superhydrophobic Ag/Cu groove track switched the path of rolling 5 μL water drops without contact on a 3-inlet, 4-outlet track.
0162014Summary based on the full text
Nanoscale Research Letters, 9, 610 (2014)
Device integration and packagingFoundations · connection under review
Adding 0.01 wt.% carbon nanotubes to a flexible polymer X-ray detector raised sensitivity from 12.5 to 38.9 μC/mGy/cm3 at 150 V; 0.005 wt.% gave a better SNR.
0152014Summary based on the full text
RSC Advances, 4(104), 60123-60130 (2014)
Device integration and packagingFoundations · connection under review
A 2 nm coupled APTMS-MPA monolayer raised the Cu barrier's t63.2 four-fold over APTMS, comparable to 50 nm TaN, and annealed Cu/SiO2 adhesion energy by 33%.
0142014Summary based on the full text
Advanced Materials, 26 (41), 7043-7050 (2014)
Materials in contact with tissueFoundations · connection under review
Hydrogen-switchable Pd/Si nanowires held hanging culture drops for human stem cell spheroids that secreted more VEGF than spinner-flask or petri-dish spheroids.
0132014Summary based on the full text
ACS Applied Materials & Interfaces, 6 (12), 9053-9060 (2014)
Device integration and packagingFoundations · connection under review
Capillary forces of water printed Ag nanoparticle line arrays from buckled templates onto flat substrates without glue; the SERS arrays detected R6G at 10⁻¹² M.
0122013Summary based on the full text
ACS Nano, 7 (12), 10809-10817 (2013)
Device integration and packagingFoundations · connection under review
Polymer AC electroluminescent devices with carbon nanotubes, micelles and polymer blends gave blue, green and red emission of about 2300, 6000 and 5000 cd m⁻².
0112013Summary based on the full text
Advanced Materials, 25 (30), 4139-4144 (2013)
Biological responses and surface designFoundations · connection under review
Hydrogen-induced expansion of Pd on DTS-coated silicon nanowires switched droplets from rolling off to pinned; air restored roll-off within 3 s, over 50 cycles.
0102013Summary based on the full text
Thin Solid Films, 527, 179-185 (2013)
Biological responses and surface designFoundations · connection under review
Cyclic rapid thermal annealing in oxygen made silicon nanowire arrays superhydrophobic yet water-adhesive (CA 154.3°); air storage restored superhydrophilicity.
0092012Summary based on the full text
Thin Solid Films, 524, 1-19 (2012)
Device integration and packagingFoundations · connection under review
A 2012 review of nanomaterials on flexible substrates for piezoelectric energy harvesting, chemical and pressure sensing, and bio-integrated electronics.
0082012Summary based on the full text
Small, 8 (10), 1614-1621 (2012)
Device integration and packagingFoundations · connection under review
Silicon nanowires aligned at micro-engraved grooves during droplet evaporation were gravure-printed onto plastic, giving FETs with 17.1 cm²/V·s hole mobility.
0072012Summary based on the full text
Journal of Nanoparticle Research, 14(5), 840 (2012)
Device integration and packagingFoundations · connection under review
Rapid thermal oxidation and HF etching smoothed electroless-etched p–n+ silicon nanowires, raising forward current density about 6.3-fold at 4 V.
0062011Summary based on the full text
ACS Applied Materials & Interfaces, 3 (12), 4722-4729 (2011)
Device integration and packagingFoundations · connection under review
UV patterning of a DTS coating on superhydrophobic Si nanowires formed erasable hydrophilic tracks that guided 8 μL droplets at 6.91 cm/s at a 5° tilt.
0052011Summary based on the full text
Journal of the Korean Physical Society, 59 (2), 501-504 (2011)
Device integration and packagingFoundations · connection under review
Aqueous electroless etching made Si/SiGe/Si PIN nanowire photodiodes with a reverse dark current of 9.2 × 10⁻⁶ A, against 1.0 × 10⁻² A for bulk devices.
0042011Summary based on the full text
Applied Surface Science, 257 (11), 4973-4977 (2011)
Device integration and packagingFoundations · connection under review
ZnO nanowires grown by MOCVD in KOH-etched Si microcavities had higher aspect ratio and density; UV detectors there gave an on/off ratio of 6 and a 5 s decay.
0032010Summary based on the full text
Thin Solid Films, 519 (2), 823-828 (2010)
Stretchable conductors and interconnectsFoundations · connection under review
Thermally pre-strained PDMS buckled 270 nm amorphous silicon films into wavy, random and herringbone wrinkles; 1D and random amplitudes matched c-Si models.
0022010Summary based on the full text
Japanese Journal of Applied Physics, 49(10R), 104003 (2010)
Device integration and packagingFoundations · connection under review
Larger Pt nanocrystals (15.1 to 55.2 nm) in MOS memory capacitors raised the flatband voltage shift from 5.75 to 13.05 V; the smallest retained charge best.
0012009Summary based on the full text
Applied Surface Science, 255 (8), 4616-4622 (2009)
Device integration and packagingFoundations · connection under review
H2 annealing at 623 K reduced Ga2O3 and ZnGa2O4 in co-sputtered ZnO:Ga films, lowering resistivity to 5.2 × 10⁻⁴ Ω cm with transmittance over 90% of glass.
No papers match these filters. Try another search or reset the filters.