Research context and placement
Local text confirms fiber-sensor/FPCB connections and closed-loop voltage control, supporting actual component/system integration.
Research overview and key contributions
DRESS connects a conductive fiber core and drug-loaded thermoresponsive shell to an FPCB.
It combines strain sensing with Joule-triggered release; closed-loop voltage control compensates strain-dependent temperature changes.
Open challenges
The authors identify hydrophilic-only drug loading and the need for in vivo validation.
Comparison context
Editorial comparison: match strain, fixation, temperature and drug loading; distinguish cell migration from wound healing.
Related external research
Wirelessly operated bioelectronic sutures for the monitoring of deep surgical wounds
DOI: 10.1038/s41551-021-00802-0 ↗
RFID capacitive sutures were evaluated in live pigs; DRESS adds thermal release but its checked biological tests are cellular/ex vivo.
Do not equate wireless operation with clinical or healing benefit.
Abstract checkedCorresponding-author verification
Correspondence unresolvedThis record concerns Jungmok Seo’s correspondence designation. Author order or an asterisk alone is not treated as confirmation; this check is separate from verification of the research content.
- Correspondence evidence source ↗
E-mail: [redacted]
BLS06_Nanoscale_2021_Multifunctional_Electronic_Suture_MAIN.pdf; PDF page 2 author list and affiliation emails · local_public_pdf_header_read
- Main-text review scope
- A DOI-matched local PDF supplied the abstract, §§2.1/2.9 and Conclusions; the public API abstract was cross-checked.
- Pending verification
- RSC landing/new URLs failed with 403/tool errors. Crossref supplied only a graphical caption. Verify current text, supplements and rights in school Chrome.
COVERAGE & OUTREACH
Coverage and outreach
Links are checked for their relationship to this paper. Media publication does not establish independent reporting or additional experimental validation.
BLISS 이연택 학생 Nanoscale에 논문 게재 ↗
The Yeontaek Lee/Nanoscale announcement image labels DRESS, strain monitoring, drug release, FPCB and conductive-fiber architecture, identifying #60.
Body read Read the public news JSON title/date and its linked image content (entry: ytlee-contest-2-2). Lab self-promotion; artwork is not redistributed.
Unverified candidates and access limits (1)
Unverified candidate · Nanoscale 2022 Lunar New Year Collection ↗
The indexed collection includes #60's exact title, authors and DOI.
Body access limited Direct access returned 403. Only indexed collection content was available; the year in the collection title was not treated as a publication date.
Sources and verification scope
A DOI-matched local PDF supplied the abstract, §§2.1/2.9 and Conclusions; the public API abstract was cross-checked.
- Public publication baseline ↗ · #60 · 2026-10-03
- Crossref metadata ↗: Only public bibliographic metadata registered with Crossref was checked. This does not mean that the publisher page, abstract, or full text was read; full-text verification in the school Chrome session remains pending. license_urls lists registered links and does not establish permission to redistribute text or figures. It may include TDM or posting-policy links.
- Source for updated publication metadata ↗
Bibliographic and publication-status check; separate from main-text review. - A multifunctional electronic suture for continuous strain monitoring and on-demand drug release ↗
local_pdf_read · Existing BLS06_Nanoscale_2021_Multifunctional_Electronic_Suture_MAIN.pdf; PDF pp.2-3,10 / article pp.18112-18113,18120; title and DOI matched. Checked 2026-10-03. - A multifunctional electronic suture for continuous strain monitoring and on-demand drug release. ↗
public_abstract_via_EuropePMC_API · Europe PMC REST search resultType=core, abstractText; PMID 34604894; DOI 10.1039/d1nr04508c. Checked 2026-10-03.